| Percent of High Risk Long Term Nursing Home Residents Who Have Pressure Sores: 5% |
| Percent of Long Term Nursing Home Residents Given Influenza Vaccination During the Flu Season: 90+% |
| Percent of Long Term Nursing Home Residents Who are More Depressed or Anxious: 23% |
| Percent of Long Term Nursing Home Residents Who Have Moderate to Severe Pain: 8% |
| Percent of Long Term Nursing Home Residents Who Have/Had a Catheter Inserted and Left in Their Bladder: 7% |
| Percent of Long Term Nursing Home Residents Who Lose Too Much Weight: 17% |
| Percent of Long Term Nursing Home Residents Who Spend Most of Their Time in Bed or in a Chair: 15% |
| Percent of Long Term Nursing Home Residents Who Were Assessed and Given Pneumococcal Vaccination: 90+% |
| Percent of Long Term Nursing Home Residents Who Were Physically Restrained: 0% |
| Percent of Long Term Nursing Home Residents Whose Ability to Move About in and Around Their Room Got Worse: 13% |
| Percent of Long Term Nursing Home Residents Whose Need for Help With Daily Activities Has Increased: 18% |
| Percent of Long Term Nursing Home Residents With a Urinary Tract Infection: 10% |
| Percent of Low-Risk Long Term Nursing Home Residents Who Have Pressure Sores: 0% |
| Percent of Low-Risk Long Term Nursing Home Residents Who Lose Control of Their Bowels or Bladder: 42% |
| Percent of Short Term Nursing Home Residents Given Influenza Vaccination During the Flu Season: 90+% |
| Percent of Short Term Nursing Home Residents Who Had Moderate to Severe Pain: 33% |
| Percent of Short Term Nursing Home Residents Who Were Assessed and Given Pneumococcal Vaccination: 89% |
| Percent of Short Term Nursing Home Residents With Delirium: 0% |
| Percent of Short Term Nursing Home Residents With Pressure Sores: 15% |
Nursing Home Violations by Henry County Nursing Home
|
| Health Violations: |
| Category: |
Date: |
Specific Violation: |
Scope: |
Level of Harm Caused: |
| Administration Deficiencies |
07/03/2003 |
Keep accurate and appropriate medical records. |
Isolated |
Minimal harm or potential for actual harm |
| Nutrition and Dietary Deficiencies |
07/03/2003 |
Store, cook, and give out food in a safe and clean way. |
Widespread |
Minimal harm or potential for actual harm |
| Pharmacy Service Deficiencies |
07/03/2003 |
Keep the rate of medication errors (wrong drug, wrong dose, wrong time) to less than 5%. |
Pattern |
Minimal harm or potential for actual harm |
| Quality Care Deficiencies |
07/03/2003 |
Give professional services that follow each resident's written care plan. |
Isolated |
Minimal harm or potential for actual harm |
| Quality Care Deficiencies |
07/03/2003 |
Give residents proper treatment to prevent new bed (pressure) sores or heal existing bed sores. |
Isolated |
Minimal harm or potential for actual harm |
| Environmental Deficiencies |
07/28/2004 |
Make sure that staff members wash their hands when needed. |
Isolated |
Minimal harm or potential for actual harm |
| Nutrition and Dietary Deficiencies |
07/28/2004 |
Prepare food that is nutritional, appetizing, tasty, attractive, well-cooked, and at the right temperature. |
Pattern |
Potential for minimal harm |
| Nutrition and Dietary Deficiencies |
07/28/2004 |
Store, cook, and give out food in a safe and clean way. |
Widespread |
Potential for minimal harm |
| Environmental Deficiencies |
03/02/2006 |
Provide needed housekeeping and maintenance. |
Isolated |
Minimal harm or potential for actual harm |
| Quality Care Deficiencies |
03/02/2006 |
Give residents proper treatment to prevent new bed (pressure) sores or heal existing bed sores. |
Isolated |
Actual harm |
| Resident Rights Deficiencies |
03/02/2006 |
Properly hold, secure and manage each resident's personal money which is deposited with the nursing home. |
Pattern |
Minimal harm or potential for actual harm |
| Fire Safety Violations: |
| Category: |
Date: |
Specific Violation: |
Scope: |
Level of Harm Caused: |
| Exits and Egress Deficiencies |
07/10/2003 |
exits that are accessible at all times. |
Pattern |
Potential for minimal harm |
| Smoke Compartmentation and Control Deficiencies |
07/10/2003 |
walls or barriers that prevent smoke from passing through and would resist fire for at least one hour. |
Pattern |
Potential for minimal harm |
| Smoke Compartmentation and Control Deficiencies |
07/10/2003 |
smoke barrier doors that can resist smoke for at least 20 minutes. |
Pattern |
Potential for minimal harm |
| Corridor Walls and Doors Deficiencies |
08/03/2004 |
corridor and hallway doors that block smoke. |
Widespread |
Potential for minimal harm |
| Electrical Deficiencies |
08/03/2004 |
properly installed electrical wiring and equipment. |
Isolated |
Minimal harm or potential for actual harm |
| Exits and Egress Deficiencies |
08/03/2004 |
exits that are accessible at all times. |
Widespread |
Potential for minimal harm |
| Hazardous Area Deficiencies |
08/03/2004 |
construction that can resist fire for one hour or an approved fire extinguishing system. |
Isolated |
Minimal harm or potential for actual harm |
| Smoke Compartmentation and Control Deficiencies |
08/03/2004 |
smoke barrier doors that can resist smoke for at least 20 minutes. |
Isolated |
Minimal harm or potential for actual harm |
| Smoking Regulations Deficiencies |
08/03/2004 |
posted No-smoking signs in areas where smoking is not permitted or did not provide ashtrays where smoking was allowed. |
Pattern |
Potential for minimal harm |
| Building Service Equipment Deficiencies |
03/08/2006 |
properly protected cooking facilities. |
Isolated |
Minimal harm or potential for actual harm |
| Corridor Walls and Doors Deficiencies |
03/08/2006 |
corridor and hallway doors that block smoke. |
Widespread |
Potential for minimal harm |
| Electrical Deficiencies |
03/08/2006 |
properly installed electrical wiring and equipment. |
Isolated |
Minimal harm or potential for actual harm |
| Fire Alarm Systems Deficiencies |
03/08/2006 |
an approved installation, maintenance and testing program for fire alarm systems. |
Pattern |
Minimal harm or potential for actual harm |
| Miscellaneous Deficiencies |
03/08/2006 |
fire safety features required by current fire safety codes. |
Isolated |
Minimal harm or potential for actual harm |
| Smoke Compartmentation and Control Deficiencies |
03/08/2006 |
walls or barriers that prevent smoke from passing through and would resist fire for at least one hour. |
Pattern |
Minimal harm or potential for actual harm |